Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
  Cellular Concrete Equipments
             
  C. C. AND ITS APPLICATIONS
   Compressive Strenght
   Thermal and Acoustic Insul.
   Characteristics
   Application
   Quality Control
   Catalogue
 

By only weighing the CC, we can check the moist working density and with the tables provided can read off the rest of the properties (compressive strength, sound and thermal insulation, etc).

RECOMMENDED DOSES OF WATER PER SACK OF CEMENT

Kg per sack of cement Water litres
Recommended MIN MAX
25 16 15 19
30 19 17 22
35 22 20 26
42,5 26 24 32
50 31 28 37


CORRESPONDENCE BETWEEN MOIST DENSITY, DRY DENSITY, CONSUMPTION OF CEMENT IN Kg/m3 AND COMPRESSIVE RESISTENCE IN Kg/cm2

MOIST DENSITY(1)
Kg/m3

DRY DENSITY(2)
Kg/m3

CEMENT CONSUMPTION
Kg/m3

COMPRESSIVE RESISTANCE(3)

THERMAL RESISTENCE(4)
m2 ºC / W

THERMAL CONDUCTIVITY(4)
W / m ºC

Kg/cm2 MPa
200 172 123 X X 1.86 0.05
225 193 138 X X 1.78 0.06
250 215 154 X X 1.70 0.06
275 236 168 2.5 0.24 1.63 0.06
300 258 184 4.6 0.45 1.55 0.06
325 279 200 6.6 0.65 1.47 0.07
350 301 215 8.7 0.85 1.40 0.07
375 322 230 10.8 1.06 1.32 0.08
400 344 246 12.9 1.26 1.24 0.08
425 365 261 14.9 1.46 1.17 0.09
450 387 276 17.0 1.67 1.09 0.09
475 408 292 19.1 1.87 1.01 0.10
500 430 307 21.1 2.07 0.93 0.11
525 451 322 23.2 2.28 0.86 0.12
550 473 338 25.3 2.48 0.78 0.13
575 494 353 27.4 2.68 0.70 0.14
600 516 368 29.4 2.89 0.63 0.16
625 537 384 31.5 3.09 0.55 0.18
650 559 399 33.6 3.29 0.47 0.21
675 580 414 35.7 3.50 0.40 0.25
700 602 430 37.7 3.70 0.32 0.31
725 623 445 39.8 3.90 0.24 0.41
750 645 461 41.9 4.11 0.17 0.60
775 666 476 43.9 4.31 0.09 1.10
800 688 491 46.0 4.51 X X
825 709 507 48.1 4.72 X X
850 731 522 50.2 4.92 X X
875 752 537 52.2 5.12 X X
900 774 553 54.3 5.33 X X

(1) The results in moist density are freshly made, in liquid state.
(2) The results in dry density are at 28 days of hardening.
(3) Results that are obtained from tests which were carried out in our laboratories. All the information is only for guidance.
Type of cement which was used Portland CEM-II/A-M(V-L) 32.5N
(4) Conductivity and thermal resistance for a filling of cellular concrete of 10 cm.



 
© Dosificadores García Fernández   |   Privacy    |   Use and Conditions   |   HOME